TAS PowerTek Ltd.
Leading through Technology

Automatic Power Factor Controllers

APFC-07 (Relay output)

Economical value for money product
Small size version in 96mm X 96mm
Wide range Voltage supply 90Vac to 500Vac OR 100Vdc to 550Vdc
5Amp and 1Amp CT connection
Models available as 4, 6 & 8 relay contacts
Large Size LCD display
Protection to Capacitor Banks


User Manual  Operations Guidelines

APFC-03 (Relay output) & TPFC-03 (Transistor output)

Fully Automatic Set-up
Wide range Voltage supply 90Vac to 500Vac OR 100Vdc to 550Vdc
5Amp and 1Amp CT connection
Measurement accuracy Class 1 for Voltage and Current. And Class 2 for Power (Active and Reactive)
Multifold Protections to Capacitor Banks
High speed switching transistor output for TPFC-03 to control high speed capacitor thyristor switches
Expert mode programming for finer aspects of PF compensation

User Manual   Operations Guidelines

SPF-56 (Relay output) / TPF-56 (Transistor output)

3-ph (3W/4W) sensing with 3 CTs.
Unit with Communication capability on Serial (RS-232C/RS485HD),
Wide range Voltage 90Vac to 500Vac OR 100Vdc to 550Vdc
5Amp and 1Amp CT connection
Models available up to 16 capacitor banks control
Data Logging with user programmability
TPF-56 comes with high speed KVAR compensation capability
Class 1 Load manager functionality

User Manual  Operations Guidelines

HTPF-56 (up to 33kV and 50MVA)

3-ph (3W/4W) sensing with 3 CTs. Additional 3 CT for capacitor current measurement
Unit with Communication capability on Serial(RS-232C/RS485HD), GSM/GPRS
Separate measurement Voltage and wide range AC/DC auxiliary supply
5Amp and 1Amp CT connection for supply & capacitor current
Models available up to 8 capacitor banks control
Data Logging with user programmability
Class 1 Load manager functionality

 

Automatic Power Factor Controller [ HTPF-03 ]

Totally Micro-controller controlled Digital Signal processing logic for measurements, monitoring, controls and logging etc.
Voltage & Current measurements with Class-2 accuracy.
Load V, I, and Cap. current THD measurement with odd harmonic coefficients up to 15th harmonic. Neutral current analysis too.
Various modes for switching, viz:
* Binary
* Un-equal (user defined)
* C-Series (preset series)
* E-Series (user defined)
Output banks control for 16 banks and 8 banks.
Capable of doing kVAr measurements every cycle of the mains waveform.


User Manual

Hand Held Unit (APFC DATA COMMUNICATOR)

Downloads four months logged data of Controller (APFC) into Hand Held Unit.
Fully Microcontroller based unit.
The captured data store into external Flash Memory (Micro SD card) which can store up to 999 controllers’ data.
Downloaded data can be fetched to PC from HHU via PC end software.
HHU can be used as a Firmware Downloader via JTAG Interface.
Portable unit.



User Manual

Auto-Manual Controller (AMC)

TAS Make Auto-Manual Controller (AMC) is an Intelligent Electronic Controller designed to allow the User to switch on or off the capacitor bank either automatically (command received from the APFC Controller as Input to the AMC) or manually, from the AMC front panel toggle switches.
TAS APFC Units also have a Manual Mode of Operation, it requires the User to operate the APFC Front Panel Switches and read the LCD Display to select the Capacitor Bank to be turned On or Off in the Manual Mode. However, some Users prefer operation with front-panel using conventional Toggle Switches. So, the AMC will provide them the comfort and ease of operations.


Auto Manual Controller