Single Phase Lighting Controller

Features :

The Lighting Controller unit offers a complete solution for Fluorescent Lighting applications with energy saving and PF improvement.

The unit comprises of controller , a high efficiency voltage reduction unit, Smart switching unit and PF improvement unit .

Energy Saving is achieved by the advanced design and intelligent logic of the controller .

They come equipped with following outstanding features :

1) ON/OFF Controls of Lamps : Fix time as per preset in controller.

2) Energy Saving : By reducing the voltage applied to lamps during non peak hours (programmable) and during over voltage condition.

3) Flicker Free Operation : Using fast and highly advanced high speed thyristorised switching logic called “Gapless Changeover”.

4) PF Improvement : By adding capacitor to compensate for inductive VAR for approximately 50 % of load.

5) Manual Operation : For “Out of Schedule” operation and testing of unit during commissioning.


TAS PowerTek Ltd.
TAS PowerTek Ltd. User Manual


3 Phase Lighting Controller

Features :

TAS PowerTek LtdThe Lighting Controller unit offers a complete solution for Fluorescent Lighting applications with energy saving and PF improvement.
TAS PowerTek LtdThe unit comprises of controller , a high efficiency voltage reduction unit, Smart switching unit and PF improvement unit .
TAS PowerTek Ltd Energy Saving is achieved by the advanced design and intelligent logic of the controller .

They come equipped with following outstanding features :
1) ON/OFF Controls of Lamps : Fix time as per preset in controller.
2) Energy Saving : By reducing the voltage applied to lamps during non peak hours (programmable) and during over voltage condition.
3) Flicker Free Operation : Using fast and highly advanced high speed thyristorised switching logic called “Gapless Changeover”.
4) PF Improvement : By adding capacitor to compensate for inductive VAR for approximately 50 % of load.
5) Manual Operation : For “Out of Schedule” operation and testing of unit during commissioning.
6) Easy Installation : Wall mounting and only three connection --I/P, O/P And N.
7) Response To Load Variation – It gives response to load variation in Energy Saving Mode. If new load is switched-on, then unit comes to bypass mode from ESM mode so lamps are on at full voltage (The levels are user settable).
8) Powder Coated cabinet- RAL 7035. (ie- Siemens gray color).
9) Complete unit bypass switch for operational redundancy.